Is it possible to extract the control signals of the processor corresponding to the RTL code of the or1200 processsor for a given set of instructions ?

Is it possible to extract the control signals of the processor corresponding to the RTL code of the or1200 processsor for a given set of instructions ?

Hi, We found a mismatch between the RTL and netlist in the or1200_genpc module. Whenever the SPR data changes, the CPU address is updated in the netlist, whereas in the...

Hi, We found a output mismatch between the RTL and the netlist of the or1200 cpu output port (du_lsu_load_dat) orginating from the LSU module of the port. ![image (1)](https://github.com/user-attachments/assets/489550e0-e974-4f6c-ab6e-a3a140280f5c) ![image](https://github.com/user-attachments/assets/10bfefde-2598-4459-8468-52d537df5a4e)

Hi, We found a mismatch between the RTL and netlist for some instructions. The PC and executed instruction value do not match. ![Image](https://github.com/user-attachments/assets/2bfdc207-0dab-4ff0-9bb5-cc11534aacda) ![Image](https://github.com/user-attachments/assets/41eff0ac-b590-4f12-9ff9-413fd4342631) ![Image](https://github.com/user-attachments/assets/d123c1e8-6757-4ba6-bf10-14f994a8a3ac) ![Image](https://github.com/user-attachments/assets/64bd8bf5-0641-4397-a3fc-0d073dce6b0d)