obadawi
obadawi
I believe you are right and the continuous periodic data reflects spo2 On Fri, Apr 1, 2022, 20:43 qwe1256 ***@***.***> wrote: > Hi, > > The description of the vitalPeriodic...
That is the "active upon discharge" flag so the way to interpret "False" is that the patient had the IABP removed prior to discharge from their ICU stay. On Mon,...
This is a good analysis of the data and shows the importance of really understanding the data source. I'll try to explain why you're seeing these patterns... First, it's important...
Good question... if a continuous infusion is documented directly in the eICU software, the users must explicitly define the drug concentration and therefore you will have both the drug rate...
One thing to keep in mind is that the diagnosis strings are not ICD 9 or 10 diagnoses. They were custom made and the codes you see were generated by...
This would have been part of the original software system used in clinical care. So there won't be any scripts or mapping that would be available to my knowledge. On...
My understanding is this was part of the Philips software used to manage patients (eCareManager). This same software was used by all the eICU systems across all hospitals. The research...
The medications table will represent the "order" as it was verified by the pharmacist. The pharmacists will generally estimate the start time or round to standard times such as 8am...
The APACHE admission dx system used does not have many choices for sepsis but you should be able to find it under the cardiovascular system diagnoses. This will provide the...
Yes but be aware that the past history table is generally not thoroughly documented so absence of a dx listed does not necessarily mean there is not a past history...