njbinbin

Results 9 comments of njbinbin

I found that if you call PMU.sleep twice after analogRead, the second will work...

Have you finished your project? I want to use 4G module on S3 with camera too...

又做了些测试,发现只要是在电池耗尽状态,再接入外部电源,电池也充不进电,树莓派也开不了机,放几个小时都是这个状态。把开关关掉至少充五分钟电再开,才能进入边充边放状态顺利开机。我不懂硬件,但感觉这里的逻辑应该是这样的:外部电源供电时,稳压后直供负载,同时给电池充电(正规UPS应该都是这样工作的,否则也不会标注0延时切换)。而这块板子给人的感觉是外部电源先给电池充电,再通过电池给负载供电(不存在切换过程),而耗尽电的电池电压不足,无法提供负载开机而白白消耗,如果是这个原理,应该读取电池电压,达到一定阈值时才对外供电。看过一块专业的UPS板是这么介绍的,但是价格太贵了。。。

大家都关注自动关机,通电以后的自动开机就没人关心吗?

用了个折衷的办法,外部电源接UPS板的同时,再同时接树莓派的电源输入口,这样树莓派同时从排针接到UPS电源,和从USB接入电源。测试了一块板子,似乎可以工作,但另一块板子就没那么幸运了,固定排针的热熔胶全化了,电池烫到快爆炸了。。。还好发现的早。然后,它就罢工了,RPI UPSPack字下面带散热片的芯片一插电就发烧,没有输出了

I gave up it...No matter how I tried it, even the battery with protective circuit, as long as the external power was cut off for a long time, the battery...

One conclusion is that this UPS is not suitable for unattended use, even if an API interface is available to prompt and actively shut down the battery before it runs...

Thanks for the information of booting from GPIO pull-up signal~~~