Stephen Tiedemann
Stephen Tiedemann
Many thanks for the proposal. I think it will be useful and certainly appreciate the contribution.
@artes-dev Please re-test with the current master branch. There was a bug in the computation of MIU for ISO DEP protocol which is now corrected.
ACR122U213 was the latest hardware revision I could test. You have revision 216 and I remember problem reports already for revision 215 (see #105).
Thanks @Dennovin . I think it's an implementation error that the command exchange time depends on the "turn on for .. seconds" time value. Can you confirm that with the...
There is a longer thread about ACR122 at #154.
@Dennovin The change you're suggesting affects code that is only executed when a user explicitly sets the buzzer and led to active. The log messages posted by @manuel-masiello show a...
It looks like I can't help any any further. The last reader response ISO/IEC 7816-4 status word `907F` seems pretty non-standard and is unfortunately not detailed in any of the...
Thank you @manuel-masiello. Best would be to place a tag on the reader and then switch the USB connection into the VM, so both initialization and some data exchanges are...
The password must be given as a byte sequence (ultimately a password is a sequence of bits with no relation to the concept of words). Python 3 strings are all...
Not to my knowledge. The only thing that might enable programmatic reset is to toggle USB power. But this is out of scope for the library.