In the newer version of FlowVisor, to know its version number you just have to type ./fvctl.py list-version Could you please tell more about your test script like what exactly...
Smilar to Issue15 or Issue158. Fixed by standardizing the way LLDP is handled with proper formation of TLVs. Fixed in 1.2 Committed in 6685bf82d59abf09fa1b80f23509ac8d5d7849ed
Have to further analyse if FlowVisor can fix it and if it can what would be the approach, but the problem still exists at GPO.
We have the fix for this, which is currently being tested. But the only problem with the tests are that in all our test cases, the Stats_Reply size are of...
The following was my test setup: I started a 200 host , 2 switch mininet topology connected to flowvisor which was connected to floodlight controller. A pingall was done amongst...
Ok, could you please send us the script which you are using to statically push 1000 odd rules.(along with the rules) It will be easy for me to reproduce it...
How does FV sending a continuation become illegal? When the switch can send FlowStats response with the "MORE_FLAG" set (which specifies that there are more flow stats reply messages coming...
I understand that sending 32 bytes of a message after sending a length of 96 is illegal. In your first comment you just mentioned a continuation is illegal so I...
The statsReply segment was getting cut because the range of signed shorts is till 32767, and we had assigned each segment of the statsReply to 61600 Bytes. Changed the setting...