Farzad
Farzad
Dear Pete Thanks for your response. I just have a misunderstanding here; ``` hub { nElements 1; elementProfiles (cylinder); elementData ( **// axial distance, height, diameter** (0 0.09 0.09) (0...
Dear Andrey and Pete This week I will try again to debug why code does not work without initial jet. I think zero free stream velocity for turbinesFoam must have...
Dear Andrey and Pete I started debugging the code and I almost find what is the problem with zero free stream velocity. In order to have the same results as...
I am not sure if this modification is physically correct or not(whenever **inflowVelAngleRad** is 0 degree, replace it with 5 degree) until the initial flow starts to form and then...
Dear Andrey and Pete let's talk about one problem at a time. If we choose **tutorials/axialFlowTurbineAL** as our case and inside **tutorials/axialFlowTurbineAL**. If we change the /tutorials/axialFlowTurbineAL/0/U as below; `internalField...
> That is just for the end effects correction, right? We can probably put the fix downstream where that value is used in the correction rather than assuming 5 degrees...
Dear Andrey Good diagnose. I also developed my own solution for this problem(please think about this to see which one is better and comprehensive, I will do so); ``` scalar...
I am not at home right now, did your modifications solve the problem? Do you see the current generated by proppler or we still have a problem? What I understand...
Ok, Just a small hint. Please do the below change in controldict; ``` libs ( "libturbinesFoam.so" ); DebugSwitches {axialFlowTurbineALSource 1; actuatorLineSource 1; actuatorLineElement 1;} ``` So you can debug easier....
Dear Andrey Ok, I continue debugging and we need to do another modification in the code, and we need to do this modification; ``` scalar angleOfAttackRad; if ((mag(planformNormal_)*mag(relativeVelocity_))