Dominik Kriegner

Results 82 comments of Dominik Kriegner

I think the problem originates in this module ``` $ perl -e 'use ExtUtils::Manifest; print $ExtUtils::Manifest::VERSION, $/' 1.70 ``` see: ``` $ perl -Mdiagnostics Build.PL Uncaught exception from user code:...

@nlaanait : I would be very much interested in your opinion on this issue.

Its also important to note that for `Experiment.Ang2Q` the two parameters of its constructor `idir` and `ndir` are not needed. This confuses many people which only use `Ang2Q`. When using...

One could also think of removing `Ang2HKL` and incorporate all functionality in `Ang2Q`. In fact `Ang2HKL` already now is only a wrapper around `Ang2Q`. This would make all use a...

Hello, I try to answer below. I think almost every first time user has similar questions. I hope my answers below will make things more clear. Note: I did not...

Dear @azkhadiev Let me try to attempt to answer your questions: > But I have found that after getting U matrix from 003 and 103 reflections and aplying it to...

A mesh scan should be perfectly fine for the detector calibration. The results of the calibration have to always be checked carefully, but I would hope would help with your...

> Does it matter for you how your software 'see' the detector image? I think that there are, lets say, two options: to see the image from the sample side...

I would say if your original issue is solved then you know you got it right :) I know this is little help, but its hard to say more from...

indeed this idea came already from many people. I think if one has some NIST certified cubic material one could do this. If I ever completely rewrite this part of...