Here is the 1st capture I think, on the basis it's full of f0f0f0f0f0 or f83e0f83e0. I'll leave it running and based on previous posts there should be another coming...

> We need to know what's expected to be in that data so we can find the fields. What depth value and maybe temperature would this be? I'll do a...

Just to share, i removed the battery pack from the transmitter, and re-inserted it. Below is what a go, a stream of two codes every 5 seconds or so. I...

Ok, hopefully what I'm posting is useful. Next step I understand is for me to give you an idea of what this reading relates to, in terms of oil or...

Sharing my results: The sesnor tube that drops into the oil measures 111cm. I removed it, cleaned it, put it back in, and took it out again to get a...

Also to say, I agree this sensor probably doesn't transmit as much data as the more recent sonic variants, but I'd expect it to transmit a low battery alarm (which...

Sorry, correction, bad maths above Summarising what we've seen so far, based on below I don't think the last 2 digits are a trailer as suggested in the BitBench. no...

Hi @Scoff123 - not sure I can get a measurement when Full as the Watchman is installed in the tank. Looking at the tank label I'd need 2000 litres of...

Thinking about this on the dog walk this morning. Maybe the transmission doesn't contain a depth reading, it might just contain what is displayed on the screen: 0-9 or F,...

Straight away I see xxxx xxxx xx58 and 48 in your data, same as mine for levels 3 and 2 respectively.... Not sure if it's this simple.... And in my...