Josh Bailey
Josh Bailey
At the moment yes the parameter is preserved (e.g. you might have two FAUCET stacks under the control of different controllers and configs connected together). So yes an additional port...
[diffs-1.8.9.txt](https://github.com/faucetsdn/faucet/files/2519716/diffs-1.8.9.txt) [FaucetVrfGuide.docx](https://github.com/faucetsdn/faucet/files/2519717/FaucetVrfGuide.docx)
Thanks for reporting this! Please would you try the self signed example at https://eventlet.net/doc/ssl.html? We'll also investigate.
Transparently redirect (say) DNS to a port. "Port security"/MAC learning limiting.
Probably we went a new item under dps for meter_ids to push (default a dp gets all).
FAUCET tracks learning state at a port, host and VLAN level. Scraping Gauge is not a good solution because Gauge doesn't know anything about learning - it's scrapes flow tables.
Sure, it should stay synchronized with the flow table. That's a bug. However inferring the learning state from the flow table as a general rule is going to be hard...
[crash.zip](https://github.com/magenta/note-seq/files/5790404/crash.zip)
I have built an open source MIDI interface that uses the user port, for precisely this reason (so I can leave my u2+ installed): https://github.com/anarkiwi/vessel (there is SID Wizard and...
I don't believe HPE support the dec TTL action, which we need to implement routing. Also, most hardware OF switches don't completely local disable VLAN processing. It would be ideal...