Results 1 issues of amkurtis

### Link https://www.samotech.co.uk/products/zigbee-switch-sm308-2ch/ ### Database entry {"id":2,"type":"Router","ieeeAddr":"0x9035eafffeef8a34","nwkAddr":30043,"manufId":4107,"manufName":"Samotech","powerSource":"Mains (single phase)","modelId":"SM308-2CH","epList":[1,2,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":256,"inClusterList":[0,3,4,5,6,1794,2820,2821,4096],"outClusterList":[25],"clusters":{"genBasic":{"attributes":{"modelId":"SM308-2CH","manufacturerName":"Samotech","powerSource":1,"zclVersion":3,"appVersion":0,"stackVersion":0,"hwVersion":1,"dateCode":"NULL","swBuildId":"2.5.3_r2"}},"genOnOff":{"attributes":{"onOff":0,"onTime":0}},"haElectricalMeasurement":{"attributes":{"rmsCurrent":5,"activePower":1,"rmsVoltage":2363,"acVoltageMultiplier":1,"acVoltageDivisor":10,"acCurrentMultiplier":1,"acCurrentDivisor":1000,"acPowerMultiplier":1,"acPowerDivisor":10}},"seMetering":{"attributes":{"currentSummDelivered":[0,3906704],"multiplier":1,"divisor":3600000}}},"binds":[{"cluster":0,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":3,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":2820,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":1794,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1}],"configuredReportings":[{"cluster":2820,"attrId":1291,"minRepIntval":5,"maxRepIntval":3600,"repChange":1},{"cluster":2820,"attrId":1288,"minRepIntval":10,"maxRepIntval":3600,"repChange":10},{"cluster":2820,"attrId":1285,"minRepIntval":10,"maxRepIntval":3600,"repChange":1},{"cluster":1794,"attrId":0,"minRepIntval":5,"maxRepIntval":3600,"repChange":[1,1]}],"meta":{}},"2":{"profId":260,"epId":2,"devId":256,"inClusterList":[0,3,4,5,6,1794,2820,2821,4096],"outClusterList":[25],"clusters":{"genBasic":{"attributes":{"appVersion":0,"stackVersion":0}},"genOnOff":{"attributes":{"onOff":0}},"haElectricalMeasurement":{"attributes":{"rmsCurrent":0,"activePower":0,"rmsVoltage":2361}},"seMetering":{"attributes":{"currentSummDelivered":[0,3906324]}}},"binds":[{"cluster":7,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":0,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":3,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":6,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":2820,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1},{"cluster":1794,"type":"endpoint","deviceIeeeAddress":"0x00124b0026b69ecc","endpointID":1}],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":102,"inClusterList":[33],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":0,"stackVersion":0,"hwVersion":1,"dateCode":"NULL","swBuildId":"2.5.3_r2","zclVersion":3,"interviewCompleted":true,"meta":{"configured":1717205429},"lastSeen":1669651239045,"defaultSendRequestWhen":"immediate"} ### Comments Switch functionality and overall energy consumption works. Is there a way to force per endpoint figures to overall? I'm...

new device support