StarMonkey1

Results 14 comments of StarMonkey1

> See #2244 > > Open questions: > > * [ ] How long does the pairing/test mode last? (the captures are only 30 secs). Seems to be around 5...

> Thanks! Over all very much like the "Standard" model/protocol then. If you monitor the data over the next weeks, note that "flags" and "alarm" are just two raw bytes...

Yup, I've built from the feat-oilsmart branch and I've left it running in an Ubuntu VM (rather than docker). Fingers crossed no hardware crashes overnight. I think the oil monitor...

Ok, so I left it collecting data overnight and while it has now identified the data and rtl_433 recognises it the data contained within must be being decoded incorrectly. rtl_433...

I'm now getting depth readings. model: oil-ultrasonic id: bd01 flags: 17 alarm: 36 binding_countdown: 0 depth_cm: 51 I've no idea if this depth reading is correct at the moment, I'll...

We've used oil since yesterdays comment (smart display shows less in litres) but the depth_cm is still reading 51 so I don't think it's decoding the correct part of the...

> > I'll attempt to get the sensor out today to see if that makes a difference. > > Can you simply compare the reading you got before and after...

[191222_capture.csv](https://github.com/merbanan/rtl_433/files/10267412/191222_capture.csv) This is the last ~24hrs

depth_cm: 52 flags are 17 and alarm 30 or 32. Anything else I should be doing/testing at the moment?

This is looking good, I've got data since my last post and everything seems pretty stable. To bottom out the depth I stuck a pole to the base of the...