Results 6 comments of MCUer

hi,paweljasinski: Speed value must be one of these constants: 9600 (default), 19200, 38400, 57600, 115200, 230400 or 460800.", uiPortSpeed); It's in the file “uart.c”. But 115200 is the PN532's default...

Please refer to the diagram: ![image](https://github.com/nfc-tools/libnfc/assets/152157872/da0b8484-8919-4332-98e9-6143cd9719a1) To be sure that the baud rate-"Real HSU Freq" error is not greater than 4%: ![image](https://github.com/nfc-tools/libnfc/assets/152157872/cfb2c6c8-bc8f-4894-a82f-35fafacbf897) [PN532 User Manual V0.2.pdf](https://github.com/nfc-tools/libnfc/files/14584891/PN532.User.Manual.V0.2.pdf) [PN532_C1.pdf](https://github.com/nfc-tools/libnfc/files/14584892/PN532_C1.pdf)

Poll the command "SAMConfiguration" at different baud rates before communication, such as: 55 55 00 00 00 00 00 00 00 00 00 00 00 00 00 00 FF 03...

> Can let CU to emulate a PN532, all usb serial port data translation to pn532 register one by one. I used AD156(Jieli MCU) to emulate PN532, and it works...

> When connected to a PC via USB it would be amazing if the Chameleon Ultra could be used with LibNFC-based tools like mfoc, mfcuk, etc. > > Is this...

大佬,我目前在用MCU模拟PN532,HardNested使用MifareOne Tool能正常使用。 用这里的release版本,出现的现象和楼主一样。 大佬有计划修正吗?