Martin Rätz
Martin Rätz
I am sorry for not having any experience with the verification cases. Working on another issue I just stumbled on this inconstancy. @MichaMans, @PRemmen do you think this is a...
Just to keep things together, I want to add that https://github.com/RWTH-EBC/TEASER/issues/637 is related to that topic.
Another enhancement regarding unit tests, could be unit tests including the use of the current AixLib version. Master -> Master Dev -> Dev
In boundaryconditions.py line 125 "min_air_exchange" is a wrong unit stated. Following DIN V 18599-10 correct would be [m³/hm²]. "min_air_exchange" is currently not used!
@marcusfuchs I did not inspect the respective code pieces. But I can see from my simulation results, that Teaser should do some conversion. But I cannot clarify, whether it does...
I have done another (Azimuth) check: TEASER Input: 90 -> east TEASER Output: -1.57 -> east So I think everything is correct. If you will do more tests, please share...
I share the opinion of @MichaMans. But as you mentioned @marcusfuchs, catching those exceptions and transferring the calculation to python sounds very reasonable to me.
This change would also break my codes, as I initiate "zones" from a building plan converted to an excel file to model huge buildings like hospitals. To me, the current...
@MichaMans Thank you for revising! My main goal was to open a discussion and think about a good way for implementation. As my opinion is not strong in this, I...
Thank you for these information! Regarding the calculation within the ROM, I do think the error occurs only with the two element thermal zone. In this particular case the area...