Jörg Giencke
Jörg Giencke
### Describe the issue A) Bei der Druckausgabe sollte 'Preis pro Sunde' rechtsbündig sein - wie alle Preise, B) Dann wäre es schön, wenn man 'Preis pro Stunde' abkürzen könnte...
### I'm sure that - [X] This issue is still present in the **current beta version** of this adapter - [X] There is no other (open) issue with the same...
### I'm sure that - [X] This issue is still present in the **current beta version** of this adapter - [X] There is no other (open) issue with the same...
Der Adapter funktioniert, aber ich bekomme bei jeder Abfrage folgende Fehlermeldung (PLENTICORE plus 8.5): `plenticore.0 | 2025-01-08 13:06:43.029 | warn | Requesting settings - [{"moduleid":"devices:local","processdataids":["Dc_P","DigitalIn","EM_State","HomeBat_P","HomeGrid_P","HomeOwn_P","HomePv_P","Home_P","Inverter:State","LimitEvuAbs"]},{"moduleid":"devices:local:ac","processdataids":["CosPhi","Frequency","L1_I","L1_P","L1_U","L2_I","L2_P","L2_U","L3_I","L3_P","L3_U","P","Q","S"]},{"moduleid":"devices:local:battery","processdataids":["Cycles","SoC","I","U","P"]},{"moduleid":"devices:local:pv1","processdataids":["I","U","P"]},{"moduleid":"devices:local:pv2","processdataids":["I","U","P"]},{"moduleid":"scb:export","processdataids":["PortalConActive"]},{"moduleid":"scb:statistic:EnergyFlow","processdataids":["Statistic:Autarky:Day","Statistic:Autarky:Month","Statistic:Autarky:Total","Statistic:Autarky:Year","Statistic:EnergyHome:Day","Statistic:EnergyHome:Month","Statistic:EnergyHome:Total","Statistic:EnergyHome:Year","Statistic:EnergyHomeBat:Day","Statistic:EnergyHomeBat:Month","Statistic:EnergyHomeBat:Total","Statistic:EnergyHomeBat:Year","Statistic:EnergyHomeGrid:Day","Statistic:EnergyHomeGrid:Month","Statistic:EnergyHomeGrid:Total","Statistic:EnergyHomeGrid:Year","Statistic:EnergyHomePv:Day","Statistic:EnergyHomePv:Month","Statistic:EnergyHomePv:Total","Statistic:EnergyHomePv:Year","Statistic:OwnConsumptionRate:Day","Statistic:OwnConsumptionRate:Month","Statistic:OwnConsumptionRate:Total","Statistic:OwnConsumptionRate:Year","Statistic:Yield:Day","Statistic:Yield:Month","Statistic:Yield:Total","Statistic:Yield:Year","Statistic:CO2Saving:Day","Statistic:CO2Saving:Month","Statistic:CO2Saving:Year","Statistic:CO2Saving:Total"]}]) failed with code 503: {"message":"internal...
Nach Update auf 0.3.4 erscheint nach Start einer Instanz folgender Fehler im Log: Sentry disabled, error catched: State attribute definition missing for 'rfid' with value 'false' and type of value...
Since version 1.2.4 backups to UNC-paths fail. Backups to local folders still work fine. When backing up to UNC-paths only one small file per Shelly device is created with this...