### Describe the bug **[TC-OO-2.3]** Test case is failing by throwing an error `Test Step Error: Error occurred during execution of test case TC-OO-2.3. no close frame received or sent`...

### Feature Area Other ### Test Case TC-TMP-2.1 ### Reproduction steps 1. Execute the below mentioned command to put DUT into a commissionable state : `./chip-all-clusters-app` 2. Once DUT reach...

bug
needs triage

### Feature Area Area:Refrigerators ### Description: In **Refrigerator And Temperature Controlled Cabinet Mode Cluster** `StartUpMode` and `OnMode` attributes are marked as provisional in spec. So it should be removed from...

bug
cert blocker
needs triage
refrigerators

### Feature Area Area:Dishwashers **Description:** In **Dish Washer Mode Cluster** `StartUpMode` and `OnMode` attributes are marked as provisional in spec. So it should be removed from the Sample app(All-cluster-app). **Specification...

bug
cert blocker
needs triage
dishwashers

### Description: In **Laundry Washer Mode Cluster** `StartUpMode` and `OnMode` attributes are marked as provisional in spec. So it should be removed from the Sample app(All-cluster-app). **Specification References:** - https://github.com/CHIP-Specifications/connectedhomeip-spec/blob/master/src/app_clusters/Mode_LaundryWasher.adoc#5-attributes...

bug
cert blocker
needs triage

### Describe the bug While executing TC-SWTCH-2.2, 2.3, 2.5, 2.6 Python scripts in UI, these test cases are failing with below error. In matter_Testing_support file line number 1904 get_accepted_endpoints_for_test function...

Bug
v1.4
QA
Needs Triage
sve_1.4
target_for_1_4_release_sve

### Feature Area Other ### Test Case TC-SWTCH-2.2 TC-SWTCH-2.4 ### Description - [ ] **TC-SWTCH-2.4** - In the test plan, there are test steps 6a, 6b, 6c, and 6d, but...

bug
cert blocker
needs triage

### Description: - [ ] 1. Below following `Feature` and `Attributes` are Disallowed for the Device Energy Management Mode Cluster. So these should be removed from the Device Energy Management...

bug
spec
needs triage
energy
energy DEM
v1.4

### Description: - [ ] 1. Below following `Feature` and `Attributes` are Disallowed for the Water Heater Mode Cluster. So these should be removed from the Water Heater Mode Cluster...

bug
spec
needs triage
water heater
v1.4

### Description: Below following `Feature` and `Attributes` are Disallowed for the Oven Mode Cluster. So these should be removed from the Oven Mode Cluster device XML. **Feature** 1. OnOff **Attributes**...

bug
spec
needs triage
ovens