Hi @1226Wang1226, I have 2 recommendations for you: 1. ~U102~ U103 only has one inlet stream. I believe it should be two. Maybe fixing this will help correct the rest...
@1226Wang1226, Sorry, I meant to say U103 (not U102). Happy the timing worked out well. I was a little worried you might have gotten stuck and started focusing on other...
@wenjung2, thanks for posting the code. Could you also simplify it to a minimal reproducible example? Since the problem is just the MeOH synthesis reactor, we just need the MeOH...
@zasddsgg, the bubble and dew points (temperatures at the bottom and top) are correct for these compositions. What is happening is that your separation specification is so small, that you...
Will do! Thanks for your patience.
@zasddsgg, downgrade your numpy version to lower than version 2.0. I'll get back to answering your most pressing questions at the end of the week. Thanks,
@XingdongShi, very cool! Could you add a readme with information about the project, a simple example usage, the authors, and any related publications? Also, it helps to note which biosteam...
@FengxuSysbio, Thanks for submitting this error. It is difficult to understand what might be source of the error, but I suspect it has to do with a version of some...
@FengxuSysbio, Yes it looks like there is some problems in your Anaconda distribution. Scipy 1.15.2 has been out since February. Potentially, the error has to do with that warning you...
@aiical, @FengxuSysbio, The issue has been solved. It turns out that certain operating systems may load the chemical database in an unexpected way. The solution was just to specify the...