Hi,

I use the provided checkpoint on BSD500, and try to reproduce numbers in the paper, but I can only get results: nC = 200; ASA: 0.959617 BR: 0.733322, nC = 400; ASA: 0.967188 BR: 0.804939

But from the plot you showed in the paper, it seems you could get >96 ASA when nC = 200 and >81 BR when nC = 400, I'm wondering is this the checkpoint you used in the paper? there seems a slight mismatch with it.