fix: Adjust actuator pins for 20A versions Sonoff ESP32 devices

Open zandegran opened this issue 1 year ago • 6 comments

Adjust actuator pins for 20A version Sonoff ESP32 devices

zandegran avatar Oct 28 '24 19:10 zandegran

Thank you! Your solution is so much more elegant than what I had started...

Unfortunately the 20A versions don't have two relays but one bi-stable relay and two pins to control it. I think this will need a few more adjustments. I'll have to think about that.

jonathanschneider avatar Oct 28 '24 20:10 jonathanschneider

I see 🤔 I will also think.. I just followed the pinout here

zandegran avatar Oct 28 '24 20:10 zandegran

That's exactly the resource I've been using... 😂

jonathanschneider avatar Oct 28 '24 20:10 jonathanschneider

@jonathanschneider one workaround could be assigning one pin as Chamber heater.. In that way when the cooler pin turns off and the fridge is not really off. But soon the algorithm would kick in and start the heater that does not exist and that would turn the fridge off..

zandegran avatar Oct 28 '24 20:10 zandegran

That might work for some time but if the device was unplugged while the relay was activated it would start cooling when plugged in again even when it shouldn't.

jonathanschneider avatar Oct 28 '24 20:10 jonathanschneider

Yes, and should eventually correct itself.

zandegran avatar Oct 28 '24 20:10 zandegran