ReciPro icon indicating copy to clipboard operation
ReciPro copied to clipboard

SpotID v1 (zone axis)

Open yoshiA3 opened this issue 2 years ago • 2 comments

Thank you Dr. Sato for producing ReciPro which is very useful software for me. The zone axis was outupted as [00-1] (please find an attaced file). This means that the c-axis direction is under the screan (left-handed system). Is it correct? 2023-12-20083714

yoshiA3 avatar Dec 20 '23 00:12 yoshiA3

The answer to your question is almost yes. The direction of the zone axis is toward the back of the screen. However, the coordinate system in ReciPro is right-handed.

By double-clicking on the output crystal axis, you can change the crystal orientation. Please give it a try.

seto77 avatar Dec 20 '23 05:12 seto77

Thank you for your reply. I was able to check the crystal orientation by double-clicking on the output. Thank you.

yoshiA3 avatar Dec 23 '23 03:12 yoshiA3