enviroplus-python icon indicating copy to clipboard operation
enviroplus-python copied to clipboard

BME280 - Pressure / Humidity Incorrect Readings

Open myte77 opened this issue 3 years ago • 1 comments

I've been using my enviro for a couple of years, writing out to InfluxDB no problem. Today however, humidity has started reading 0 and pressure is way too high. It just dropped off, everything else seems as normal. Anyone else have this or can recommend a fix? Screenshot 2022-07-21 062129

myte77 avatar Jul 21 '22 05:07 myte77

Sorted it. It was following a power cut. Could have been something that affected it. Just unplugged everything and reconnected and all back up.

myte77 avatar Jul 21 '22 05:07 myte77

Good to close?

andypiper avatar Aug 17 '22 14:08 andypiper

All good.. thank you.

myte77 avatar Aug 17 '22 14:08 myte77