LM System Heater implementation

Open rcflyinghokie opened this issue 8 years ago • 6 comments

All of the heaters in the LM are currently just connected to radiators and effectively do not do anything. As the systems are made to generate heat for the glycol loop, the LM active heaters need to be looked at and wired up appropriately to the systems themselves and either radiators or the glycol loop, and then wired for proper power draw and subsequently to the SCEA for temperature monitoring.

rcflyinghokie avatar Dec 31 '17 17:12 rcflyinghokie

#234

rcflyinghokie avatar Jan 02 '18 00:01 rcflyinghokie

Update: All heaters in the LM have been implemented, and routed through the proper breakers and SCEA's as necessary, as well as systems that reject heat to glycol.

What remains is power/heat generated by systems exhausted into the cabin (eg component lights) and LGC, CDU, PSA, LCA, DSE, PTA, ECA, & battery heat to the glycol once those systems are fully implemented.

rcflyinghokie avatar Mar 26 '18 22:03 rcflyinghokie

Heat sinks in LM will be implemented soon so the heat loads arent directly transmitted to the glycol, radiators will allow both loops to share the heat and the active loop to remove it from the radiator instead of "splitting" the heat 50/50 which is not realistic

rcflyinghokie avatar Jul 07 '18 14:07 rcflyinghokie

Computer heat generation implemented #373

rcflyinghokie avatar Jul 26 '18 09:07 rcflyinghokie

With update #603, LM cold plates implemented and battery heat added. LM systems still awaiting heat generation: CDU, PSA, LCA, PTA, SPA, ECA.

rcflyinghokie avatar Apr 19 '21 18:04 rcflyinghokie

#609 Adds initial PTA and PSA heat