[HCL] PowerWalker Basic VI 850 SB supported by usbhid-ups
PowerWalker Basic VI 850 SB
upsc output
Init SSL without certificate database
battery.charge: 97
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: 1
battery.runtime: 2280
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 13.6
battery.voltage.nominal: 12
device.mfr: 1
device.model: 850
device.serial: 000000000000
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/hidraw0
driver.parameter.productid: 0601
driver.parameter.synchronous: no
driver.parameter.vendorid: 0764
driver.version: 2.7.4
driver.version.data: CyberPower HID 0.4
driver.version.internal: 0.41
input.transfer.high: 290
input.transfer.low: 162
input.voltage: 235.0
input.voltage.nominal: 0
output.voltage: 237.0
ups.beeper.status: disabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 6
ups.mfr: 1
ups.model: 850
ups.productid: 0601
ups.realpower.nominal: 480
ups.serial: 000000000000
ups.status: OL CHRG
ups.timer.shutdown: -60
ups.timer.start: -60
ups.vendorid: 0764
upscmd -l PowerWalker
Instant commands supported on UPS [PowerWalker]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
load.on - Turn on the load immediately
load.on.delay - Turn on the load with a delay (seconds)
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test
Link to the manufacturer’s online description of the device https://powerwalker.com/product/10121067/
lsusb reports the UPS as a "CyberPower System PR1500LCDRT2U" but it's a "PowerWalker Basic VI 850 SB".
Bus 001 Device 002: ID 0764:0601 Cyber Power System, Inc. PR1500LCDRT2U UPS
My system:
Distributor ID: Ubuntu
Description: Ubuntu 22.04.3 LTS
Release: 22.04
Codename: jammy
Network UPS Tools upsc 2.7.4
Sorry if I don't include more information (such as "shutdown sequence testing results"). I have no idea what it is and how I should do it. But in the end I haven't yet tested whether the computer shuts down and I'm not sure I've configured everything correctly either. I'm a novice and already happy to have been able to connect the "not supported" UPS to Ubuntu 22.04. And the monitoring through the server by Home Assistant also works. If any further information is required, then please help me with the commands I need to enter.