PCA9685 not working due to onLoop() is not called

Open sepo83 opened this issue 6 years ago • 3 comments

The libraries SensorPca9685W, SensorPca9685RGB and SensorPca9685RGBW require their onLoop() function to be called every loop in order to do the color/pwm change. It seems that in V1.8 of NodeManager this is not done every loop.

Workaround: Call the onLoop()-function directely in the loop-funtion of the sketch. For example: led_b1_rgb.onLoop(NULL);

Is there any "cleaner" solution?

sepo83 avatar Jun 10 '19 19:06 sepo83

Hi, thanks for reporting this issue. Theoretically onLoop() is called at any loop() since the latter is just wrapping the first one unless skipped because sleeping or because of a reporting timer set. Isn't it the case? Thanks

user2684 avatar Jun 12 '19 07:06 user2684

After doing some debugging I think it has something to do with the reporting timer. Every loop I get _evaluateTimer(_measure_timer)=0, _measure_timer=1174, message=0 (debug print was set at the first line of Sensor::loop)

Do I have to set this timer somehow?

I defined the following: #define NODEMANAGER_DEBUG ON #define NODEMANAGER_INTERRUPTS ON #define NODEMANAGER_SLEEP OFF #define NODEMANAGER_RECEIVE ON #define NODEMANAGER_DEBUG_VERBOSE ON #define NODEMANAGER_POWER_MANAGER OFF #define NODEMANAGER_CONDITIONAL_REPORT OFF #define NODEMANAGER_EEPROM OFF #define NODEMANAGER_TIME OFF #define NODEMANAGER_RTC OFF #define NODEMANAGER_SD OFF #define NODEMANAGER_HOOKING OFF #define NODEMANAGER_OTA_CONFIGURATION OFF #define NODEMANAGER_SERIAL_INPUT OFF

I configured/set nothing else in before().

sepo83 avatar Jun 12 '19 18:06 sepo83

Theoretically, when you set a report timer and if a measure timer is not set explicit, it is just copied over. However, you can set just the measure timer if you wish with:

Sensor::setMeasureTimerMode(timer_mode value)
Sensor::setMeasureTimerValue(unsigned long value)

Something like:

setMeasureTimerMode(TIME_INTERVAL)
setMeasureTimerValue(60)

This is because there is no equivalent for setReportIntervalSeconds() for measure timer, you have to call both explicitly. Try give it a try, if it works, we will add this into this sensor code so the user does not have to make it explicit. Thx

user2684 avatar Jul 22 '19 13:07 user2684