spec icon indicating copy to clipboard operation
spec copied to clipboard

Add additional descriptions of the device

Open petrvanekrobe opened this issue 5 years ago • 10 comments

Data with examples:

Minimum distances Min. distance from flammable surfaces: 1 m Min. distance to lighted object: 3 m

Total heat dissipation: 3240 BTU/hr (calculated)

Ingress protection rating: • CE: IP 67 • US: Suitable for wet location

Max. static load (Used for inground devices) • Standard tempered glass: 45kN • Antiskid tempered glass: 23kN

Cooling system • Convection • Forced air

petrvanekrobe avatar Dec 10 '20 12:12 petrvanekrobe

I think the IP thing is a good thing. I'm just doing over audio, and I think this is part of every data sheet there as well. Mentioning the IP def seems to be easy!

moritzstaffel avatar Apr 05 '24 12:04 moritzstaffel

We can add them to the

PhysicalDescriptions.Properties

Properties Collect

General

This section defines the general properties of the device type (XML node <Properties>). The Properties Collect currently does not have any XML attributes. The currently defined children nodes of properties collect are specified in table 28.

Table 28. Properties Collect

XML node Amount Description
OperatingTemperature 0 or 1 Temperature range in which the device can be operated.
Weight 0 or 1 Weight of the device including all accessories.
PowerConsumption Any Power information for a given connector.
LegHeight 0 or 1 Height of the legs.
IP 0 or 1 String of the IP rating.
BTU 0 or 1 heat dissipation in BTU/hr.
MaxStaticLoad 0 or 1 Force in kN that this floor light can withstand.
DistanceToFlammable 0 or 1 Distance in meter from flammable objects.
DistanceToOther 0 or 1 Distance in meter from other objects.

The only thing I'm not sure if what the cooling system is @petrvanekrobe Can you provide more info

moritzstaffel avatar Apr 10 '24 14:04 moritzstaffel

Max. static load IK Rating

moritzstaffel avatar Apr 11 '24 12:04 moritzstaffel

Sound pressure level: 27 dB(A) at 1 m (quiet mode) 42 dB(A) at 1 m (auto mode) Sound power level: 35 dB(A) (quiet mode) 50 dB(A) (auto mode)

moritzstaffel avatar Apr 11 '24 12:04 moritzstaffel

We want

  • IP
  • Distances

BTU can be calculated, But petr checks

moritzstaffel avatar Apr 11 '24 12:04 moritzstaffel

BTU can be calculated, so we will not add this.

moritzstaffel avatar Apr 18 '24 12:04 moritzstaffel

  • Robe defined data: Min. distance from flammable materials: 1 m is a required information about distance from flammable materials based on surface temperature of the fixture's housing. This is defined in EN IEC 60598-2-17 part 2-17, section 17.6.4 - minimal distance from flammable materials of all outer surfaces of the device.

  • Robe defined data: Min. distance of illuminated objects: 18 m is a required information about distance on which the fixture could make illuminated surface warmer then 90°. This is defined in EN IEC 60598-1, part 1, section 3.2.13. Often accommodated by this picture:

image

petrvanekrobe avatar May 02 '24 12:05 petrvanekrobe