Add additional descriptions of the device
Data with examples:
Minimum distances Min. distance from flammable surfaces: 1 m Min. distance to lighted object: 3 m
Total heat dissipation: 3240 BTU/hr (calculated)
Ingress protection rating: • CE: IP 67 • US: Suitable for wet location
Max. static load (Used for inground devices) • Standard tempered glass: 45kN • Antiskid tempered glass: 23kN
Cooling system • Convection • Forced air
I think the IP thing is a good thing. I'm just doing over audio, and I think this is part of every data sheet there as well. Mentioning the IP def seems to be easy!
We can add them to the
PhysicalDescriptions.Properties
Properties Collect
General
This section defines the general properties of the device type (XML node
<Properties>). The Properties Collect currently does not have any XML
attributes. The currently defined children nodes of properties collect
are specified in table 28.
Table 28. Properties Collect
| XML node | Amount | Description |
|---|---|---|
| OperatingTemperature | 0 or 1 | Temperature range in which the device can be operated. |
| Weight | 0 or 1 | Weight of the device including all accessories. |
| PowerConsumption | Any | Power information for a given connector. |
| LegHeight | 0 or 1 | Height of the legs. |
| IP | 0 or 1 | String of the IP rating. |
| BTU | 0 or 1 | heat dissipation in BTU/hr. |
| MaxStaticLoad | 0 or 1 | Force in kN that this floor light can withstand. |
| DistanceToFlammable | 0 or 1 | Distance in meter from flammable objects. |
| DistanceToOther | 0 or 1 | Distance in meter from other objects. |
The only thing I'm not sure if what the cooling system is @petrvanekrobe Can you provide more info
Max. static load IK Rating
Sound pressure level: 27 dB(A) at 1 m (quiet mode) 42 dB(A) at 1 m (auto mode) Sound power level: 35 dB(A) (quiet mode) 50 dB(A) (auto mode)
We want
- IP
- Distances
BTU can be calculated, But petr checks
BTU can be calculated, so we will not add this.
-
Robe defined data: Min. distance from flammable materials: 1 m is a required information about distance from flammable materials based on surface temperature of the fixture's housing. This is defined in EN IEC 60598-2-17 part 2-17, section 17.6.4 - minimal distance from flammable materials of all outer surfaces of the device.
-
Robe defined data: Min. distance of illuminated objects: 18 m is a required information about distance on which the fixture could make illuminated surface warmer then 90°. This is defined in EN IEC 60598-1, part 1, section 3.2.13. Often accommodated by this picture: