Add additional descriptions of the device

Open moritzstaffel opened this issue 1 year ago • 2 comments

Implements #45

moritzstaffel avatar Apr 18 '24 11:04 moritzstaffel

Summery of discussion: The distance need more definition, as it is not clear what they actually do and how do we define this. Laser, CO2 Cannon, Pyro: Do they need this as well.

moritzstaffel avatar Apr 18 '24 12:04 moritzstaffel

  • Robe defined data: Min. distance from flammable materials: 1 m is a required information about distance from flammable materials based on surface temperature of the fixture's housing. This is defined in EN IEC 60598-2-17 part 2-17, section 17.6.4 - minimal distance from flammable materials of all outer surfaces of the device.

  • Robe defined data: Min. distance of illuminated objects: 18 m is a required information about distance on which the fixture could make illuminated surface warmer then 90°. This is defined in EN IEC 60598-1, part 1, section 3.2.13. Often accommodated by this picture:

image

petrvanekrobe avatar May 02 '24 12:05 petrvanekrobe