USR-W630 IncompleteReadError

Open swildig opened this issue 1 year ago • 0 comments

Issue related to

Sunsynk / mbusd Home Assistant Add-On

Describe the issue/bug

I'm having trouble connecting to a sunsynk 8.8kw ECCO via a USR-W630. It doesn't even log the serial number from the inverter and every read errors with an "IncompleteReadError".

The inverter shows an ID of "01" so I've tried setting the "MODBUS_ID" to both 1 and "01" but neither seem to have any effect. I've also set READ_SENSOR_BATCH_SIZE to 8 as I've seen mentioned but that doesn't seem to help.

I've tried all 4 "Data Transfor Mode"s on the W630 and both inverter drivers in the addon.

I'm at a bit of a loss for what else to try, any help would be appreciated.

Your environment

  • Home Assistant version: 2024.5.0
  • Addon:
    • Name: sunsynk-multi
    • Version: 0.6.5
  • Inverter:
    • Make: Sunsynk
    • Model: SYNK-8K-SG05LP1
    • Firmware: COMM:E426 - MCU:5382-1515
    • Adaptor details:
    • RS485 - USR-W630

Logs

17:55:14 INFO    Loading configuration: /data/options.json
17:55:14 INFO    sunsynk library version: 0.6.4
17:55:14 INFO    Schedules:
+-----------+-----+------+--------+-----------+----------+------------+
|    Key    | src | Read | Report | Change by | Change % | Change any |
+-----------+-----+------+--------+-----------+----------+------------+
| date_time |     |  60  |   60   |           |          |    True    |
|     rw    |     |  5   |  300   |           |          |    True    |
|     w     |  *  |  5   |   60   |     80    |          |            |
|    kwh    |     | 300  |  300   |           |          |            |
|  any_unit |     |  15  |  300   |           |          |            |
|  no_unit  |     |  15  |  300   |           |          |    True    |
+-----------+-----+------+--------+-----------+----------+------------+
17:55:14 INFO    Using Single phase sensor definitions.
17:55:14 INFO    Added hidden sensors as other sensors depend on it: Rated power, Serial
17:55:14 INFO    Connecting to tcp://192.168.100.216:8899
17:55:14 INFO    Reading startup sensors Prog4 Time, Prog3 Time, Prog5 Time, Prog6 Time, Rated power, Prog2 Time, Prog1 Time, Battery Low Capacity, Serial
17:55:18 ERROR   IncompleteReadError reading 5 registers from 3: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 2 registers from 16: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 1 registers from 219: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 6 registers from 250: 0 bytes read on a total of 9 expected bytes
17:55:22 ERROR   IncompleteReadError reading 5 registers from 3: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 2 registers from 16: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 1 registers from 219: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 6 registers from 250: 0 bytes read on a total of 9 expected bytes
17:55:26 ERROR   IncompleteReadError reading 5 registers from 3: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 2 registers from 16: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 1 registers from 219: 0 bytes read on a total of 9 expected bytes; IncompleteReadError reading 6 registers from 250: 0 bytes read on a total of 9 expected bytes
17:55:26 WARNING Retrying individual sensors: ['prog4_time', 'prog3_time', 'prog5_time', 'prog6_time', 'rated_power', 'prog2_time', 'prog1_time', 'battery_low_capacity', 'serial']
17:55:27 ERROR   IncompleteReadError reading 1 registers from 253: 0 bytes read on a total of 9 expected bytes Prog4 Time
17:55:28 ERROR   IncompleteReadError reading 1 registers from 252: 0 bytes read on a total of 9 expected bytes Prog3 Time
17:55:29 ERROR   IncompleteReadError reading 1 registers from 254: 0 bytes read on a total of 9 expected bytes Prog5 Time
17:55:30 ERROR   IncompleteReadError reading 1 registers from 255: 0 bytes read on a total of 9 expected bytes Prog6 Time
17:55:31 ERROR   IncompleteReadError reading 2 registers from 16: 0 bytes read on a total of 9 expected bytes Rated power
17:55:32 ERROR   IncompleteReadError reading 1 registers from 251: 0 bytes read on a total of 9 expected bytes Prog2 Time
17:55:34 ERROR   IncompleteReadError reading 1 registers from 250: 0 bytes read on a total of 9 expected bytes Prog1 Time
17:55:35 ERROR   IncompleteReadError reading 1 registers from 219: 0 bytes read on a total of 9 expected bytes Battery Low Capacity
17:55:36 ERROR   IncompleteReadError reading 5 registers from 3: 0 bytes read on a total of 9 expected bytes Serial
17:55:36 CRITICAL Could not read sensors: ['Prog4 Time', 'Prog3 Time', 'Prog5 Time', 'Prog6 Time', 'Rated power', 'Prog2 Time', 'Prog1 Time', 'Battery Low Capacity', 'Serial']
17:55:36 INFO    ############################################################
17:55:36 INFO    No response on the Modbus interface tcp://192.168.100.216:8899, see https://kellerza.github.io/sunsynk/guide/fault-finding
17:55:36 INFO    ############################################################
17:55:36 CRITICAL This Add-On will terminate in 30 seconds, use the Supervisor Watchdog to restart automatically.