Wondering if the A Matrix is missing a (times) dt factor

Open otmanon opened this issue 5 years ago • 0 comments

Hey! I'm implementing something similar following Bridson's textbook as well! Sometimes I look at this codebase as a reference ;) Wondering however whether or not this is a mistake on my end or not. It seems the A Matrix as constructed in your pressureSolve() function has coefficients that are not multiplied by the timestep length, as the textbook suggests they should be.

Maybe you just assume a timestep of 1 and that works out for you? Thanks

otmanon avatar Jul 27 '20 00:07 otmanon