ebusd-configuration icon indicating copy to clipboard operation
ebusd-configuration copied to clipboard

VR70 and VR71 config

Open odewdney opened this issue 1 year ago • 0 comments

When you set the VR7x configuration in your VRCxxx it sets up the VR7x so it knows which inputs are VR10 or VR11 etc, and which relays control mixer valves:

VR70

Request: 10 52 b523 (9) Data: 00

sensor: 0=VR10,1=VR11,2=demand relay: 1=mixer

cfg  r3 r5 s1 s2 s3 s4 s5 s6 
  1: 00 01 00 02 02 00 00 00 : ma-r3/4 s6->r5/6
  2: 00 01 00 00 02 00 00 00 : ma
  3: 00 01 00 00 00 00 00 00 : ma-r1 s6->r5/6
  4: 00 00 00 00 00 00 00 00 : --
  5: 01 01 00 02 02 00 00 00 : -- s5->r3/4 s6->r5/6
  6: 00 00 00 00 00 00 01 00 : ma-r3/4
  7: 00 00 00 00 00 00 00 00 : ma
  8: 00 00 00 00 00 00 00 00 : ma
  9: 00 00 00 00 00 00 00 00 : --
 10: 00 00 00 00 00 00 00 00 : --
 11: 00 00 00 00 00 00 00 00 : --
 12: 00 01 00 00 00 00 01 00 : -- s6->r5/6

VR71

Req: 10 26 b523 (11) Data: 04

sensor: 0=VR10,1=VR11,2=demand,3=PWM


                 ss ss ss ss ss ss
                 12 34 56 78 91 11
cfg                           0 12
  1: 01 01 00 00 00 00 01 02 00 03
  2: 01 01 01 00 00 00 01 00 00 03
  3: 01 01 00 00 00 20 22 00 00 00
  6: 01 01 01 00 00 00 00 22 02 00

I am not sure about the first 4 bytes in the VR71 config - it looks like they should be mixer control, but config-3 has 3 mixer zones, and i guess the 4th byte is unused, as the "R13" connection in the VR71 seem to be not an output at all.

this was using info from https://professional.vaillant.co.uk/downloads/product-manuals/vrc-700/vrc-700-installation-instructions-1968307.pdf page 33

odewdney avatar Feb 01 '25 13:02 odewdney