Global pressure solvers do not consider DEVC activation of OBST
Here is a simple test case to demonstrate that the global solvers (UGLMAT, ULMAT, USCARC) all need to consider OBST time activation, as this is an often used feature in FDS.
I‘ll have a look
Am 25.01.2022 um 17:20 schrieb Randy McDermott @.***>:
Assigned #10271https://github.com/firemodels/fds/issues/10271 to @SusanKilianhttps://github.com/SusanKilian.
— Reply to this email directly, view it on GitHubhttps://github.com/firemodels/fds/issues/10271#event-5951134342, or unsubscribehttps://github.com/notifications/unsubscribe-auth/ADYYOFPHADZTFAN5OSBWJNDUX3EUPANCNFSM5MYWTRAQ. Triage notifications on the go with GitHub Mobile for iOShttps://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675 or Androidhttps://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub. You are receiving this because you were assigned.Message ID: @.***>
In addition to the OBST activation, we need to make sure that the LEAK model works when an opening or closing of a zone occurs. The test cases to look at here are the zone_break cases in fds/Verification/Pressure_Effects. When I try the latest USCARC on theses cases, I get a seg fault.
Follow the logic of MERGE_PRESSURE_ZONES in divg.f90. I think all the global solvers need to address this.
Okay, I will work from here and also look at the LEAK zone model ...