Values on display don't match reported values
Hey there,
I have a weird issue where the temperature values shown on the display are in 9/10 cases not matching the values reported via Zigbee, even waiting 30s (default display refresh timeout) doesn't fix it. They're always off ~.2°C. Is that known or did I miss a setting somewhere? I did not do any calibration, I just flashed the latest firmware and that's it.
Thanks and greetings,
Andy!
What version of firmware is reported in z2m or zha interface?
"Unknown":
I've flashed the latest from this repo, 1.1.0
I also observe this behavior with my newly flashed LYWSD03MMC using 1.1.0. In ZHA the firmware is displayed as "unknown". No manual configuration, like calibration, of the device happened. I tried looking for values wich set the refresh intervals for display and Zigbee but was unable to find it.
Same problem here. Temperature and humidity doesn't match the value on the display.
Edit: The screen is completely freezed on same value all the time. Doesn't change.
I have the same issue. On the display always showing 0.6 C offset temperature. Humidity value displayed correctly. I am using latest fw (1.1.0) and z2m.