code_saturne icon indicating copy to clipboard operation
code_saturne copied to clipboard

Problem with the update for the scheme choice with Gas Combustion

Open YohannEude opened this issue 5 years ago • 2 comments

Hi,

When you use the Gas Combustion model with the D3P model (I didn't try for the other combustion models) and with non adiabatic option to activate the enthalpy, the choice for the scheme is not taking account when I compare the setup.log for the 3 variables :

  • enthalpy
  • mixture_fraction
  • mixture_fraction_variance

Regards,

Yohann

YohannEude avatar Nov 18 '20 09:11 YohannEude

Hello,

It is not clear to me which scheme is not taken into account, and to which reference this is compared.

YvanFournier avatar Dec 29 '20 11:12 YvanFournier

Hi,

It is about the choice in the Scheme column in the panel Equation parameters for the three variables (enthalpy, mixture_fraction and mixture_fraction_variance) which are not updated when I compared in the setup.log with different choice for the scheme. Maybe it is because the scheme choices are fixed for this module d3p.

YohannEude avatar Dec 29 '20 12:12 YohannEude