To add a detail: When the issue appears, it's cyclic, but the issue doesn't always appear, see graphs from yesterday and today (which is also reflected in the logs): ![Image](https://github.com/user-attachments/assets/0541fd82-d6ef-4b85-9201-f12246a381c8)

Some further analysis: I sniffed the wifi traffic between the inverter and the access point at the time when the issue appears. On most polling intervals, the tcp streams looks...

Hi @mawoka-myblock , thanks for getting back! I checked the pcap file for `/getOutputData` streams and they all look pretty normal over the entire capture, similar to this: ![Image](https://github.com/user-attachments/assets/b517ecab-3959-4f56-9f72-780563acf023) All...

> Have you all check the issue with the APsystem support? The problem is that I/we don't have any other information on what's going on inside the inverter. I only...

> Hello, is this one originaly 600w or 800w? which version of Firmware has the EZ-1, cant find this info above. Should be be 800W originally. You're right, I missed...

I got response from the APSystems support which didn't shed any light: `Dear Customer, We suggest you use the EasyPower app to monitor your device. If the problem still exists,...

> I've patched my APSystems integration to circumvent this problem. Since a few days, I'm not getting any `InverterReturnedError`, and the values never transition to `unavailable` (I've added an automation...