Not save zero demands and reference to the default pattern for each junction?
Currently junctions with zero demand values are also saved into the [DEMANDS] section. This does not add any new information and makes the INP file larger. The GUI does not do that. I suggest not to save these zero demands.
All junctions without a demand pattern are set to follow the default pattern (if exists). When saved, all these junctions are saved with the default pattern which makes this setting redundant. I suggest not to save the pattern ID for junctions which follow the default one.
Thoughts?
OK, plan to move on this one...
This will have to wait a bit until we can read the demand categories names (#290). I think that we would like to save zero demands for demand categories unless there is only one category with no name.
Moving this to v2.3
This issue has been addressed by PR #702 and can be closed.