A lot of messages: "EventBus error 'OnEvent/deviceMessage': ZCL command ..... timed out after 10000ms"
What happened?
Hi,
With this device:
- Model: ZWT199/ZWT100-BH
- Zigbee Model TS0601
- Manufactured: _TZE204_lzriup1j
I get a lot of "EventBus error" messages every second.
Thanks in advance for your support!
What did you expect to happen?
Don't have any of this messages
How to reproduce it (minimal and precise)
Only to pair this device in zigbee2mqtt and you will see those messages.
Zigbee2MQTT version
1.40.0
Adapter firmware version
20240510
Adapter
SLZB-06M
Setup
Docker container
Debug log
error 2024-09-06 14:16:41z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":237},"zclSequence":40,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:16:53z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":125},"zclSequence":98,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:17:24z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":139},"zclSequence":177,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:17:34z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":192},"zclSequence":188,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:17:55z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":135},"zclSequence":128,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:18:51z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":47},"zclSequence":133,"commandIdentifier":11} timed out after 10000ms) error 2024-09-06 14:19:11z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xXXXXXXXXX/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30621,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":223},"zclSequence":61,"commandIdentifier":11} timed out after 10000ms)
Same here.
same here. z2m 1.40.1 on docker unraid, skyconnect, emberznet
after comment 'external_converters' in configuration.yaml and restart z2m there are no that messages in log
after comment 'external_converters' in configuration.yaml and restart z2m there are no that messages in log
In my case, I don't use external_converters option.
It looks like the device is not reachable somehow, does it still happen when re-pairing it close to the coordinator?
There are less than 1.5 meters between them. They are in the same room. 1.5 meters is enough or maybe should I connect them closer together?
It looks like the device is not reachable somehow, does it still happen when re-pairing it close to the coordinator?
Hi, I've tried to repair the device near the coordinator and the problem is the same. Any advice?
Hi, I'm having the same problem with a similar device:
Model: ZWT198/ZWT100-BH ZigBee Model: TS0601 Device: _TZE200_viy9ihs7
ZigBee adapter: SLZB-06M ZigBee adapter firmware version: 20240510 Coordinator type: EmberZNet Coordinator revision: 7.4.1 [GA] ZigBee2MQTT version: 1.40.1 zigbee-herdsman-converters version: 20.12.1 zigbee-herdsman version: 0.57.3
After successfully pairing it, every ten seconds or so, I'm seeing a bunch of messages like these:
[20241001:174759] error: z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xb43a31fffe3d296a/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":143}) [20241001:174809] error: z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xb43a31fffe3d296a/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":229}) [20241001:174835] error: z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xb43a31fffe3d296a/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Delivery failed for {"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":73})
Thanks
In order to add more information, I can confirm the problem exists with the newest 1.40.2 version.
Could you check if the issue is fixed with the following external converter:
- save this as file next to
configuration.yamlasext_converter.js - add it to
configuration.yaml:
external_converters:
- ext_converter.js
- start z2m,
- in the frontend, check if the description of this device now ends with
CUSTOM(this indicates the external converter has been loaded correctly) - check if issue is fixed
Hello, It seems to be working in my case, there are no errors in the Z2M and HA logs. Let's see what others say Thanks
@domome double check that all the features are still working
@domome double check that all the features are still working
Yes, everything is working properly.
Same here, now everything works ok, no more error logs. Thanks!
Same here too! It works great!! Any errors in the log file!
I wonder if it is possible to know what the problem was...
Thanks for your support @Koenkk !!
The issue with my ZWT198 thermostat is all sorted out now. There are no more error messages in the logs, and it’s working perfectly. Huge thanks for all the hard work and support.
@domome double check that all the features are still working
Hello Doing an automation in HA I just checked that it seems that the Auto and Manual function are interchanged. When Manual mode is set, the clock symbol appears on the thermostat (which is the automatic mode) and when Auto is set, a hand appears on the thermostat (which is the manual mode). Can anyone else do this check? Thank you.
@domome you can add comment here :) https://github.com/Koenkk/zigbee2mqtt/issues/23998 please also confirm your manufacturer number : _TZE204_lzriup1j
temporary you can do what I did :) https://github.com/Koenkk/zigbee2mqtt/issues/23998#issuecomment-2399162938
@domome you can add comment here :) #23998 please also confirm your manufacturer number : _TZE204_lzriup1j
It is indeed that model.
I was looking at doing a test with something like: [4, 'preset', if (device.manufacturerName === '_TZE200_viy9ihs7') or (device.manufacturerName === '_TZE204_lzriup1j')
Auto and Manual function are interchanged.
Same here
The TZE200_viy9ihs7 has the same issue with the presets. I just discovered this after reading the latest comments here.
There’s a comment in #21353 that explains the order of presets for both models, and it seems that in the code, both are reversed.
Hi All, i have similar issue but with Zigbee Model TS0601 Zigbee Manufacturer _TZE200_g9a3awaj Model [ZWT07]
Would this fix work on this model by adding external converter and changing model line?
HI, I have here a hand full of Sensors looking the same but identified as Zigbee Model TS0601 Zigbee Manufactur _TZE204_upagmta9
which show same behavior and are very coupling only after several retries. Usually they look connected but send no metrics or parts of it. It feels like there are some individual sensors that do not like coupling or fall offline after some hours.
in ZIGBEE logs the error "EventBus error 'OnEvent/deviceMessage': ZCL command ..... timed out after 10000ms" is a frequent guest
Maybe the debug log helps? Here during a coupling
info 2024-11-18 18:00:07z2m: Accepting joining not in blocklist device '0xa4c13837935c5b8c' info 2024-11-18 18:00:07z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:08+01:00","linkquality":236}' info 2024-11-18 18:00:07zh:controller: Interview for '0xa4c13837935c5b8c' started info 2024-11-18 18:00:07z2m: Device '0xa4c13837935c5b8c' joined info 2024-11-18 18:00:07z2m: Starting interview of '0xa4c13837935c5b8c' info 2024-11-18 18:00:07z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c"},"type":"device_joined"}' info 2024-11-18 18:00:07z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c","status":"started"},"type":"device_interview"}' info 2024-11-18 18:00:07z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:08+01:00","linkquality":236}' info 2024-11-18 18:00:08z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c"},"type":"device_announce"}' error 2024-11-18 18:00:18z2m: EventBus error 'OnEvent/deviceAnnounce': ZCL command 0xa4c13837935c5b8c/1 manuSpecificTuya.dataQuery({}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":30062,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":240},"zclSequence":49,"commandIdentifier":11} timed out after 10000ms) info 2024-11-18 18:00:41z2m: Accepting joining not in blocklist device '0xa4c13837935c5b8c' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:42+01:00","linkquality":236}' info 2024-11-18 18:00:41z2m: Accepting joining not in blocklist device '0xa4c13837935c5b8c' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:42+01:00","linkquality":236}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:42+01:00","linkquality":236}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c"},"type":"device_announce"}' info 2024-11-18 18:00:41zh:controller: Succesfully interviewed '0xa4c13837935c5b8c' info 2024-11-18 18:00:41z2m: Successfully interviewed '0xa4c13837935c5b8c', device has successfully been paired info 2024-11-18 18:00:41z2m: Device '0xa4c13837935c5b8c' is supported, identified as: Tuya Temperature and humidity sensor (ZTH05) info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/temperature/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"device_class":"temperature","enabled_by_default":true,"object_id":"0xa4c13837935c5b8c_temperature","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_class":"measurement","state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_temperature_zigbee2mqtt","unit_of_measurement":"°C","value_template":"{{ value_json.temperature }}"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"definition":{"description":"Temperature and humidity sensor","exposes":[{"access":1,"description":"Measured temperature value","label":"Temperature","name":"temperature","property":"temperature","type":"numeric","unit":"°C"},{"access":1,"description":"Measured relative humidity","label":"Humidity","name":"humidity","property":"humidity","type":"numeric","unit":"%"},{"access":1,"description":"State of the battery","label":"Battery state","name":"battery_state","property":"battery_state","type":"enum","values":["low","medium","high"]},{"access":3,"description":"Temperature unit","label":"Temperature unit","name":"temperature_unit","property":"temperature_unit","type":"enum","values":["celsius","fahrenheit"]},{"access":1,"category":"diagnostic","description":"Link quality (signal strength)","label":"Linkquality","name":"linkquality","property":"linkquality","type":"numeric","unit":"lqi","value_max":255,"value_min":0}],"model":"ZTH05","options":[{"access":2,"description":"Calibrates the temperature value (absolute offset), takes into effect on next report of device.","label":"Temperature calibration","name":"temperature_calibration","property":"temperature_calibration","type":"numeric"},{"access":2,"description":"Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it.","label":"Temperature precision","name":"temperature_precision","property":"temperature_precision","type":"numeric","value_max":3,"value_min":0},{"access":2,"description":"Calibrates the humidity value (absolute offset), takes into effect on next report of device.","label":"Humidity calibration","name":"humidity_calibration","property":"humidity_calibration","type":"numeric"},{"access":2,"description":"Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it.","label":"Humidity precision","name":"humidity_precision","property":"humidity_precision","type":"numeric","value_max":3,"value_min":0}],"supports_ota":false,"vendor":"Tuya"},"friendly_name":"0xa4c13837935c5b8c","ieee_address":"0xa4c13837935c5b8c","status":"successful","supported":true},"type":"device_interview"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/humidity/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"device_class":"humidity","enabled_by_default":true,"object_id":"0xa4c13837935c5b8c_humidity","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_class":"measurement","state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_humidity_zigbee2mqtt","unit_of_measurement":"%","value_template":"{{ value_json.humidity }}"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/0xa4c13837935c5b8c', payload '{"last_seen":"2024-11-18T18:00:42+01:00","linkquality":236,"temperature":null}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/battery_state/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"enabled_by_default":true,"name":"Battery state","object_id":"0xa4c13837935c5b8c_battery_state","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_battery_state_zigbee2mqtt","value_template":"{{ value_json.battery_state }}"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/temperature_unit/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"enabled_by_default":false,"name":"Temperature unit","object_id":"0xa4c13837935c5b8c_temperature_unit","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_temperature_unit_zigbee2mqtt","value_template":"{{ value_json.temperature_unit }}"}' info 2024-11-18 18:00:41z2m:mqtt: MQTT publish: topic 'homeassistant/select/0xa4c13837935c5b8c/temperature_unit/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","command_topic":"zigbee2mqtt/0xa4c13837935c5b8c/set/temperature_unit","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"enabled_by_default":true,"name":"Temperature unit","object_id":"0xa4c13837935c5b8c_temperature_unit","options":["celsius","fahrenheit"],"origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_temperature_unit_zigbee2mqtt","value_template":"{{ value_json.temperature_unit }}"}' info 2024-11-18 18:00:42z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/linkquality/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"enabled_by_default":false,"entity_category":"diagnostic","icon":"mdi:signal","name":"Linkquality","object_id":"0xa4c13837935c5b8c_linkquality","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_class":"measurement","state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_linkquality_zigbee2mqtt","unit_of_measurement":"lqi","value_template":"{{ value_json.linkquality }}"}' info 2024-11-18 18:00:42z2m:mqtt: MQTT publish: topic 'homeassistant/sensor/0xa4c13837935c5b8c/last_seen/config', payload '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0xa4c13837935c5b8c/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","device":{"identifiers":["zigbee2mqtt_0xa4c13837935c5b8c"],"manufacturer":"Tuya","model":"Temperature and humidity sensor (ZTH05)","name":"0xa4c13837935c5b8c","via_device":"zigbee2mqtt_bridge_0x8c65a3fffe5485e4"},"device_class":"timestamp","enabled_by_default":false,"entity_category":"diagnostic","icon":"mdi:clock","name":"Last seen","object_id":"0xa4c13837935c5b8c_last_seen","origin":{"name":"Zigbee2MQTT","sw":"1.41.0","url":"https://www.zigbee2mqtt.io"},"state_topic":"zigbee2mqtt/0xa4c13837935c5b8c","unique_id":"0xa4c13837935c5b8c_last_seen_zigbee2mqtt","value_template":"{{ value_json.last_seen }}"}'
Same here with ZTH01 temperature sensor.
Zigbee Model: TS0601 Zigbee Manufacturer: _TZE204_yjjdcqsq
Zigbee2MQTT version 1.42.0
Message keeps popping up even after the devices is removed from the Z2M configuration.
2025-01-02 19:17:30z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xa4c138d6e76a7d2f/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Timeout - 29665 - 1 - 44 - 61184 - 11 after 10000ms) error 2025-01-02 19:17:53z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xa4c138d6e76a7d2f/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Timeout - 29665 - 1 - 45 - 61184 - 11 after 10000ms) error 2025-01-02 19:18:17z2m: EventBus error 'OnEvent/deviceMessage': ZCL command 0xa4c138d6e76a7d2f/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Timeout - 29665 - 1 - 46 - 61184 - 11 after 10000ms)
Edit: Paired the device again, did a reboot of the HA system (not HA but the system), removed the device and now the issue is gone. I am not sure if the error did not show up anymore after the system reboot. I did remove it as I didn't want to use it anymore anyway. But it is worth the try to reboot your system to see if the error disappears.
This issue is stale because it has been open 60 days with no activity. Remove stale label or comment or this will be closed in 7 days
I started to get those errors too
EventBus error 'OnEvent/deviceAnnounce': ZCL 0x...../1 command manuSpecificTuya.dataQuery({}, ....
Check batteries...
One of my batteries leaked inside while the clock/sensor was showing last bar on battery gauge - I thought batts are still ok...
But when I pressed button the screen started to dimming/blinking and showed garbage....
I have this same error with this device: https://www.zigbee2mqtt.io/devices/PJ-1203A.html#tuya-pj-1203a
HAOS 16.2 running on RPi 4. Zigbee2MQTT 2.6.1-1 Sonoff Zigbee dongle - E with Ember 7.4.5.0
zhc:tuya: Failed respond to version response '0xa4c1384e31082f59' (Error: ZCL command 0xa4c1384e31082f59/1 manuSpecificTuya.mcuVersionRequest({"seq":2}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"reservedBits":0,"writeUndiv":false}) failed ({"target":29572,"apsFrame":{"profileId":260,"clusterId":61184,"sourceEndpoint":1,"destinationEndpoint":1,"options":4416,"groupId":0,"sequence":179},"zclSequence":133,"commandIdentifier":11} timed out after 10000ms))