zigbee2mqtt icon indicating copy to clipboard operation
zigbee2mqtt copied to clipboard

V1.37.0 Error (re)configuring Nedis Smoke Detector TS0205 in log after upgrade to V1.37.0

Open SchoutenHans opened this issue 1 year ago • 2 comments

What happened?

After upgrade to V1.37.0 errors in logfile for Nedis Smoke Detectors, Three Reconfigure attempts after restart.

Z2M Server: Failed to configure 'Smoke-2', attempt 3 (Error: Bind 0x5c0272fffec63ad9/1 genPowerCfg from '0x00124b00239325b4/1' failed (AREQ - ZDO - bindRsp after 10000ms) at Object.start (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\utils\waitress.ts:63:23) at C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\adapter\z-stack\adapter\zStackAdapter.ts:691:28 at Queue.execute (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\utils\queue.ts:35:20) at Endpoint.bind (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\controller\model\endpoint.ts:464:13) at setupAttributes (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman-converters\src\lib\modernExtend.ts:75:13) at configure (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman-converters\src\lib\modernExtend.ts:112:17) at Object.configure (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman-converters\src\index.ts:160:21) at Configure.configure (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\lib\extension\configure.ts:121:13) at Configure.onMQTTMessage (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\lib\extension\configure.ts:55:21) at EventEmitter.wrappedCallback (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\lib\eventBus.ts:174:17)) 3-5-2024 11:08:22 ZigbeePlus Error Z2M Server: Failed to configure 'Smoke-2', attempt 2 (Error: ZCL command 0x5c0272fffec63ad9/1 genPowerCfg.configReport([{"minimumReportInterval":3600,"maximumReportInterval":65000,"reportableChange":10,"attribute":"batteryPercentageRemaining"}], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 11371 - 1 - 19 - 1 - 7 after 10000ms) at Object.start (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\utils\waitress.ts:63:23) at ZStackAdapter.sendZclFrameToEndpointInternal (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\adapter\z-stack\adapter\zStackAdapter.ts:498:47) at Queue.execute (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\utils\queue.ts:35:20) at Request.send

What did you expect to happen?

No Errors

How to reproduce it (minimal and precise)

Revert to previous version 1.35.1

Zigbee2MQTT version

1.37.0

Adapter firmware version

20230507

Adapter

C2652RB Sleash

Setup

Windows

Debug log

No response

SchoutenHans avatar May 03 '24 09:05 SchoutenHans

i had the same issue for 11 Smoke detectors. a manually reconfigure or interview did not help (after pressing the button).

z2m: Failed to configure 'Schlafzimmer Rauchmelder', attempt 3 (Error: ZCL command 0x0c4314fffef32a28/1 genPowerCfg.configReport([{"minimumReportInterval":3600,"maximumReportInterval":65000,"reportableChange":10,"attribute":"batteryPercentageRemaining"}], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 20572 - 1 - 4 - 1 - 7 after 10000ms)
    at Object.start (/app/node_modules/zigbee-herdsman/src/utils/waitress.ts:63:23)
    at ZStackAdapter.sendZclFrameToEndpointInternal (/app/node_modules/zigbee-herdsman/src/adapter/z-stack/adapter/zStackAdapter.ts:498:47)
    at Queue.execute (/app/node_modules/zigbee-herdsman/src/utils/queue.ts:35:20)
    at Request.send (/app/node_modules/zigbee-herdsman/src/controller/helpers/request.ts:79:20)
    at Endpoint.zclCommand (/app/node_modules/zigbee-herdsman/src/controller/model/endpoint.ts:767:28)
    at Endpoint.configureReporting (/app/node_modules/zigbee-herdsman/src/controller/model/endpoint.ts:557:9)
    at setupAttributes (/app/node_modules/zigbee-herdsman-converters/src/lib/modernExtend.ts:107:13)
    at configure (/app/node_modules/zigbee-herdsman-converters/src/lib/modernExtend.ts:152:17)
    at Object.configure (/app/node_modules/zigbee-herdsman-converters/src/index.ts:190:21)
    at Configure.configure (/app/lib/extension/configure.ts:126:13))

b2un0 avatar Jul 22 '24 18:07 b2un0

@Koenkk,

I tried to upgrade from V 1.35.1 to V 1.39.0 to see if this problem is solved, but the errors are still there. So I'm back to V 1.35.1. again. What happened since V 1.35.1 with the Nedis Smoke Detectors? Can you solve this?

Regards, Hans

Error V1.39.0

Z2M Server: z2m: Failed to configure 'Smoke-2', attempt 2 (Error: Bind 0x5c0272fffec63ad9/1 genPowerCfg from '0x00124b00239325b4/1' failed (AREQ - ZDO - bindRsp after 10000ms) at Object.start (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\utils\waitress.ts:63:23) at C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\adapter\z-stack\adapter\zStackAdapter.ts:691:28 at Queue.execute (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\utils\queue.ts:35:20) at Endpoint.bind (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman\src\controller\model\endpoint.ts:465:13) at setupAttributes (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman-converters\src\lib\modernExtend.ts:106:13) at configure (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman-converters\src\lib\modernExtend.ts:152:17) at Object.configure (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\node_modules\zigbee-herdsman-converters\src\index.ts:190:21) at Configure.configure (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\lib\extension\configure.ts:126:13) at Configure.onMQTTMessage (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\lib\extension\configure.ts:56:21) at EventEmitter.wrappedCallback (C:\Program Files (x86)\HomeSeer HS4\Data\ZigbeePlus\zigbee2mqtt\lib\eventBus.ts:174:17))

SchoutenHans avatar Jul 28 '24 16:07 SchoutenHans

Could you provide the data/database.db entry of this device?

Koenkk avatar Jul 29 '24 17:07 Koenkk

@Koenkk

Attached the database.db file of the system running V 1.35.1 (With this version the Nedis Smoke Detectors don't generate the error)

database.zip

SchoutenHans avatar Jul 29 '24 17:07 SchoutenHans

here mine

cat /apps/zigbee2mqtt/data/database.db | grep TS0205 > /apps/zigbee2mqtt/data/database.cat.db
{"id":20,"type":"EndDevice","ieeeAddr":"0xa4c138319dcb2cdc","nwkAddr":7904,"manufId":4417,"manufName":"_TZ3210_up3pngle","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,4,5,1,1280],"outClusterList":[3,4,6,4096,10,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TZ3210_up3pngle","powerSource":3,"zclVersion":3,"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":""}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":180}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[{"cluster":1,"attrId":33,"minRepIntval":3600,"maxRepIntval":65000,"repChange":10,"manufacturerCode":null}],"meta":{}}},"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":1324213189},"lastSeen":1722304118636}
{"id":32,"type":"EndDevice","ieeeAddr":"0x5c0272fffec04418","nwkAddr":54491,"manufId":0,"manufName":"_TYZB01_dsjszp0x","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,1,3,1280],"outClusterList":[3,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TYZB01_dsjszp0x"}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":200}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[],"meta":{}}},"appVersion":64,"zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1722327958454}
{"id":66,"type":"EndDevice","ieeeAddr":"0x0c4314fffef32a28","nwkAddr":20572,"manufId":0,"manufName":"_TYZB01_dsjszp0x","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,1,3,1280,61185],"outClusterList":[3,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TYZB01_dsjszp0x","powerSource":3,"appVersion":66,"zclVersion":3}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":200,"batteryVoltage":30}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[],"meta":{}}},"appVersion":66,"zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1722316061539}
{"id":71,"type":"EndDevice","ieeeAddr":"0x0c4314fffe7277b8","nwkAddr":25162,"manufId":0,"manufName":"_TYZB01_dsjszp0x","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,1,3,1280,61185],"outClusterList":[3,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TYZB01_dsjszp0x","powerSource":3,"zclVersion":3,"appVersion":66}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":200}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[],"meta":{}}},"appVersion":66,"zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1722321794087}
{"id":72,"type":"EndDevice","ieeeAddr":"0x0c4314fffe6ad1da","nwkAddr":65447,"manufId":0,"manufName":"_TYZB01_dsjszp0x","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,1,3,1280,61185],"outClusterList":[3,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TYZB01_dsjszp0x","appVersion":66,"powerSource":3,"zclVersion":3}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":200}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[],"meta":{}}},"appVersion":66,"zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1722327629925}
{"id":90,"type":"EndDevice","ieeeAddr":"0x50325ffffe16e838","nwkAddr":41059,"manufId":0,"manufName":"_TYZB01_dsjszp0x","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,1,3,1280,61185],"outClusterList":[3,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TYZB01_dsjszp0x","appVersion":66,"powerSource":3,"zclVersion":3}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":200}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[],"meta":{}}},"appVersion":66,"zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1722320422279}
{"id":108,"type":"EndDevice","ieeeAddr":"0x50325ffffe0fb27a","nwkAddr":12681,"manufId":0,"manufName":"_TYZB01_dsjszp0x","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,1,3,1280,61185],"outClusterList":[3,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TYZB01_dsjszp0x","powerSource":3,"zclVersion":3,"appVersion":66}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":200}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[],"meta":{}}},"appVersion":66,"zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1722321490471}
{"id":120,"type":"EndDevice","ieeeAddr":"0xa4c1381528a6e702","nwkAddr":11478,"manufId":4417,"manufName":"_TZ3210_up3pngle","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,4,5,1,1280],"outClusterList":[3,4,6,4096,10,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TZ3210_up3pngle","powerSource":3,"zclVersion":3,"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":""}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":180}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[{"cluster":1,"attrId":33,"minRepIntval":3600,"maxRepIntval":65000,"repChange":10,"manufacturerCode":null}],"meta":{}}},"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":1324213189},"lastSeen":1722327310034}
{"id":135,"type":"EndDevice","ieeeAddr":"0xa4c1387efb84c594","nwkAddr":11457,"manufId":4417,"manufName":"_TZ3210_up3pngle","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,4,5,1,1280],"outClusterList":[3,4,6,4096,10,25],"clusters":{"genBasic":{"attributes":{"dateCode":""}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":144}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[{"cluster":1,"attrId":33,"minRepIntval":3600,"maxRepIntval":65000,"repChange":10,"manufacturerCode":null}],"meta":{}}},"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":1324213189},"lastSeen":1722265560221}
{"id":146,"type":"EndDevice","ieeeAddr":"0xa4c13899ea9b37f3","nwkAddr":34771,"manufId":4417,"manufName":"_TZ3210_up3pngle","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,4,5,1,1280],"outClusterList":[3,4,6,4096,10,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TZ3210_up3pngle","powerSource":3,"zclVersion":3,"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":""}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":200}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[{"cluster":1,"attrId":33,"minRepIntval":3600,"maxRepIntval":65000,"repChange":10,"manufacturerCode":null}],"meta":{}}},"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":332242049},"lastSeen":1722297395959}
{"id":147,"type":"EndDevice","ieeeAddr":"0xa4c138bbfc5c0a75","nwkAddr":36017,"manufId":4417,"manufName":"_TZ3210_up3pngle","powerSource":"Battery","modelId":"TS0205","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":1026,"inClusterList":[0,4,5,1,1280],"outClusterList":[3,4,6,4096,10,25],"clusters":{"genBasic":{"attributes":{"modelId":"TS0205","manufacturerName":"_TZ3210_up3pngle","powerSource":3,"zclVersion":3,"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":""}},"ssIasZone":{"attributes":{"iasCieAddr":"0x00124b002a2f51ad","zoneState":1}},"genPowerCfg":{"attributes":{"batteryPercentageRemaining":200}}},"binds":[{"cluster":1,"type":"endpoint","deviceIeeeAddress":"0x00124b002a2f51ad","endpointID":1}],"configuredReportings":[{"cluster":1,"attrId":33,"minRepIntval":3600,"maxRepIntval":65000,"repChange":10,"manufacturerCode":null}],"meta":{}}},"appVersion":65,"stackVersion":1,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{"configured":332242049},"lastSeen":1722305615099}

b2un0 avatar Jul 30 '24 08:07 b2un0

Fixed!

Changes will be available in the dev branch in a few hours from now.

Koenkk avatar Jul 31 '24 19:07 Koenkk

Thanks!