SigDigger icon indicating copy to clipboard operation
SigDigger copied to clipboard

Channel issue on the Power meter

Open eb3frn opened this issue 2 years ago • 2 comments

When selects the RMS inspector > Power meter, the measurement for narrow band is wrong because dont use the correct channel. It is easy to see in the Channel Config of this inspector.

Thanks!

eb3frn avatar May 11 '23 16:05 eb3frn

I am afraid I cannot reproduce. How much is "narrow"? I've just opened a 286 Hz-wide channel in a 78 kHz span and it does the measurement just fine. Left is pass-thru, right is power meter.

Captura de pantalla de 2023-05-11 18-56-53

BatchDrake avatar May 11 '23 16:05 BatchDrake

Hi @eb3frn

Do you still see this issue?

BatchDrake avatar May 15 '23 11:05 BatchDrake